Data · dataset · 2021
Pig data for 2D-3D intensity-based registration
Listed in e-cienciaDatos
A new workflow is proposed to update the intraoperative electron radiotherapy (IOERT) planning refreshing the position and orientation (pose) of a virtual applicator with respect to the preoperative computed tomography (CT) with the actual pose during surgery.
Description
The workflow proposed relies on a robust registration of the preoperative CT and intraoperative projection radiographs acquired with a C-arm system. The workflow initially performs a geometric calibration of the C-arm using fiducials placed on the applicator.
In the next step, a point-based 2D-3D registration based on fiducials positioned on the patient s skin is performed, followed by an intensity-based registration that refines the point-based registration result. The performance of the workflow has been evaluated using a realistic physical phantom consisting of a pig lower limb and its corresponding CT and 7 C-arm projections at different poses. The accuracy has been measured with respect to the applicator origin and axis before and after the registration refinement process.
Read the rest (2 more)
A feasibility study with human data is also included. Error analysis revealed angular accuracy of 0.9 ± 0.7 degrees and translational accuracy of 1.9 ± 1 mm. Our experiments demonstrated that the proposed workflow can achieve subdegree angular accuracy in locating the applicator with respect to the preoperative CT to update and supervise the IOERT planning right before radiation delivery.
The proposed workflow could be easily implementable in a routine, corresponding to a significant improvement in quality assurance during IOERT procedures.
Links
Where it is published
- Dataverse dataset page edatos.consorciomadrono.es/dataset.xhtml?persistentId=doi%3A10.21227%2FGXPD-D998 ↗
landing page · from edatos consorciomadrono es
- DOI doi.org/10.21227/gxpd-d998 ↗
DOI / persistent id · from edatos consorciomadrono es
Catalogue records · 1
- Dataverse API edatos.consorciomadrono.es/api/datasets/:persistentId/?persistentId=doi%3A10.21227%2FGXPD… ↗
metadata API · from edatos consorciomadrono es
Topics
- From keywords
- Medicine & Health
- Inferred from text
- Computed tomography 75%
Provenance · 1 source records, 7 field assertions
| Source | Key | Last seen | Raw |
|---|---|---|---|
| e-cienciaDatos | doi:10.21227/GXPD-D998 | 13 d ago | JSON v1 |
| Field | Assertion | Extractor | Evidence |
|---|---|---|---|
| concepts[field].local:field:medicine-health | mapping · edatos consorciomadrono es | connector:edatos_consorciomadrono_es@1.0.0 | /subjects |
| concepts[modality].local:modality:ct | enrichment · edatos consorciomadrono es | keyword-concept-rules@1.0.0 | title+description (75%) |
| created_date | source · edatos consorciomadrono es | connector:edatos_consorciomadrono_es@1.0.0 | |
| description | source · edatos consorciomadrono es | connector:edatos_consorciomadrono_es@1.0.0 | /description |
| publication_date | source · edatos consorciomadrono es | connector:edatos_consorciomadrono_es@1.0.0 | |
| title | source · edatos consorciomadrono es | connector:edatos_consorciomadrono_es@1.0.0 | /name |
| updated_date | source · edatos consorciomadrono es | connector:edatos_consorciomadrono_es@1.0.0 |