← Search

Data · dataset · 2026

Characterization and correction of relative humidity measurements from Vaisala RS80-A radiosondes at cold temperatures

Listed in National Center for Atmospheric Research

Radiosonde relative humidity (RH) measurements are known to be unreliable at cold temperatures.

Description

This study characterizes radiosonde RH measurements from Vaisala RS80-A thin-film capacitive sensors in the temperature range 0° to −70°C. Sources of measurement error are identified, and two approaches for correcting the errors are presented. The corrections given in this paper apply only to the Vaisala RS80-A sensor, although the RS80-H sensor is briefly discussed for comparison.

A temperature-dependent correction factor is derived from statistical analysis of simultaneous RH measurements from RS80-A radiosondes and the NOAA cryogenic frostpoint hygrometer. The mean RS80-A measurement error is shown to be a dry bias that increases with decreasing temperature, and the multiplicative correction factor is about 1.3 at −35°C, 1.6 at −50°C, 2.0 at −60°C, and 2.4 at −70°C. The fractional uncertainty in the mean of corrected measurements, when large datasets are considered statistically, increases from 0.06 at 0°C to 0.11 at −70°C. The fractional uncertainty for correcting an individual sounding is about ±0.2, which is larger because this statistical approach considers only the mean value of measurement errors that are not purely temperature dependent.

Read the rest (2 more)

The correction must not be used outside the temperature range 0° to −70°C, because it is a meaningless extrapolation of a polynomial curve fit. Laboratory measurements of sensor response conducted at Vaisala are used to characterize some of the individual sources of RS80-A measurement error. A correction factor is derived for the dominant RS80-A measurement error at cold temperatures: an inaccurate approximation for the sensor's temperature dependence in the data processing algorithm.

The correction factor for temperature-dependence error is about 1.1 at −35°C, 1.4 at −50°C, 1.8 at −60°C, and 2.5 at −70°C. Dependences and typical magnitudes are given for measurement errors that result from the temperature dependence of the sensor's time constant, and from several smaller bias errors and random uncertainties.

Links

Get the data

Where it is published

Catalogue records · 1

Topics

Provenance · 1 source records, 7 field assertions
SourceKeyLast seenRaw
National Center for Atmospheric Research50fbad48-1300-40d9-8733-a54dc5c8ab3412 d agoJSON v1
FieldAssertionExtractorEvidence
concepts[field].local:field:earth-environmentalmapping · data ucar educonnector:data_ucar_edu@1.0.0
concepts[field].local:field:ocean-atmosphericmapping · data ucar educonnector:data_ucar_edu@1.0.0
created_datesource · data ucar educonnector:data_ucar_edu@1.0.0
descriptionsource · data ucar educonnector:data_ucar_edu@1.0.0/notes
publication_datesource · data ucar educonnector:data_ucar_edu@1.0.0
titlesource · data ucar educonnector:data_ucar_edu@1.0.0/title
updated_datesource · data ucar educonnector:data_ucar_edu@1.0.0