← Search

Data · dataset · 2024

Study on the dosimetric effect of respiratory motion on boron neutron capture therapy for lung cancer

Listed in ScienceDB

[Background]: Boron Neutron Capture Therapy (BNCT) is an emerging radiotherapy technique.

Description

However, respiratory motion has a critical impact on the dose accuracy in BNCT treatment of lung cancer. [Purpose]: This study aims to quantify the dosimetric impact caused by respiratory motion during BNCT treatment of lung cancer. [Methods]: This study employs the Monte Carlo simulation method to develop a dynamic model capturing the spatiotemporal variations of tumors and organs due to respiratory motion in lung cancer treatment, and performs Monte Carlo dose calculations for BNCT.

Firstly, using the Multi-function And Generalized Intelligent Code-bench based on Monte Carlo method (MagicMC), this study modeled the adult male phantom provided by Oak Ridge National Laboratory (ORNL). Then, by incorporating high-order cosine functions that describe respiratory motion, this study established a dynamic dose calculation model. Finally, this study employed MagicMC to calculate the dose errors in tumors and organs resulting from respiratory motion in different directions within three-dimensional space. [Results]: The results indicate that during a respiratory cycle, the tumor in all three motion directions exhibits the largest percentage dose difference at the 50% phase.

Read the rest (2 more)

In the left-right direction(LR), it is 0.310%; in the anterior-posterior direction(AP), it is 5.830%; and in the superior-inferior direction(SI), it is -2.852%. The closer healthy tissues are to the irradiation field, the higher the dose rate they receive. The maximum percentage dose difference for the heart in the LR direction is 2.070%, and the maximum percentage dose differences for the right lung in the AP and SI directions are 4.128% and -11.962%, respectively.

During BNCT treatment irradiation, organ motion in the AP direction has the greatest impact on tumor dose, resulting in a dose error of 1.644%. For healthy tissues, the dose errors induced by motion in all three directions remain within ±4%. [Conclusions]: The study demonstrates that organ respiratory motion during BNCT treatment for lung cancer affects the doses received by tumors and healthy tissues, the calculation results can provide a reference for precise dose calculation and clinical irradiation dose correction in BNCT treatment of lung cancer.

Links

Where it is published

Catalogue records · 1

Topics

Inferred from text
Cancer 75% · Heart 75% · Simulation 75%
Provenance · 1 source records, 12 field assertions
SourceKeyLast seenRaw
ScienceDB10.57760/sciencedb.hjs.0018212 d agoJSON v1
FieldAssertionExtractorEvidence
concepts[anatomy].local:anatomy:heartenrichment · scidb cnkeyword-concept-rules@1.0.0title+description (75%)
concepts[disease].local:disease:cancerenrichment · scidb cnkeyword-concept-rules@1.0.0title+description (75%)
concepts[field].local:field:earth-environmentalmapping · scidb cnconnector:scidb_cn@1.0.0
concepts[field].local:field:engineeringmapping · scidb cnconnector:scidb_cn@1.0.0
concepts[field].local:field:humanitiesmapping · scidb cnconnector:scidb_cn@1.0.0
concepts[field].local:field:life-sciencesmapping · scidb cnconnector:scidb_cn@1.0.0
concepts[field].local:field:social-sciencemapping · scidb cnconnector:scidb_cn@1.0.0
concepts[method].local:method:simulationenrichment · scidb cnkeyword-concept-rules@1.0.0title+description (75%)
descriptionsource · scidb cnconnector:scidb_cn@1.0.0/metadata/dc/description
license_textsource · scidb cnconnector:scidb_cn@1.0.0
publication_datesource · scidb cnconnector:scidb_cn@1.0.0
titlesource · scidb cnconnector:scidb_cn@1.0.0/metadata/dc/title