Study on improvement of injection power for EAST-NBI

Listed in ScienceDB

In order to meet experimental requirements on high parameter plasma research, the injected power of counter injector is expected to increase at a fixed beam energy of 50keV for deuterium neutral beam.

Description

Three candidate schemes are compared to assess the possibilities of raising the injection power. Consider safety and economic factors,raising the electric field in the first gap is employed by adjusting the voltage gradient on the accelerator.

The experiments show that the optimum perveance is increased from 2.2μP to 2.7μP by changing of gradient grid voltage from 0.84Vacc to 0.78Vacc. The ion beam power is promoted by about 50% at 3.0μP. But, beam transmission efficiency decreased to 60 % at 3.0μP. Thus, the injection power is boosted about 25%. 

Links

Where it is published

Catalogue records · 1

Topics

Provenance · 1 source records, 10 field assertions
SourceKeyLast seenRaw
ScienceDB10.57760/sciencedb.0461712 d agoJSON v1
FieldAssertionExtractorEvidence
access_levelsource · scidb cnconnector:scidb_cn@1.0.0
concepts[field].local:field:earth-environmentalmapping · scidb cnconnector:scidb_cn@1.0.0
concepts[field].local:field:engineeringmapping · scidb cnconnector:scidb_cn@1.0.0
concepts[field].local:field:humanitiesmapping · scidb cnconnector:scidb_cn@1.0.0
concepts[field].local:field:life-sciencesmapping · scidb cnconnector:scidb_cn@1.0.0
concepts[field].local:field:social-sciencemapping · scidb cnconnector:scidb_cn@1.0.0
descriptionsource · scidb cnconnector:scidb_cn@1.0.0/metadata/dc/description
licensesource · scidb cnconnector:scidb_cn@1.0.0/metadata/dc/rights
publication_datesource · scidb cnconnector:scidb_cn@1.0.0
titlesource · scidb cnconnector:scidb_cn@1.0.0/metadata/dc/title